Week 16 (11/11/2019 - 15/11/2019)

Task: Updating Chapter 5. As the assessor from FYP Exhibition has been giving opinion and comment on my project, so I put it in the recommendation of Chapter 5.

Recommendations

For the recommendation, this project need a lot of improvement even though the project was successfully operated. The sensor was very sensitive and it just measure the pulse rate straightaway without knowing the persons was not in resting position.

        When observing the Serial Monitor, the heart rate measurement and track plays were displayed some error even though it played the right track. For example, the heart rate was 87 BPM and playing track 128. It should be on track 3. In the SD Card of MP3 Shield there were only four tracks. Some fix should be made in future so that it displayed the right track number with the heart rate measurement.

        As for this project only play the audio of heart rate status, it should play the number of heart rate too. Blind persons would not know the exact number of heart rate if the status only played through earphone. It may be the audio delivered as normal heart rate but the reading of BPM was 100, which nearly to higher heart rate and vice versa. The recommendation is to add more track with the number of heart rate played though earphone.

        Another recommendation is this project should use Electrocardiogram (ECG) to compare the measurement of heart rate with pulse sensor. For this project, pulse oximeter has been used to compare with pulse sensor by taking the reading displayed on the patient monitor. The pulse oximeter’s BPM reading should only the number of heart rate. To measure the exact heart rate, the ECG machine should be used and print the ECG wave on trace paper. After that measure the heart rate from R to R wave by using caliper method.

        For advanced recommendation, the data sent to the IoT should be use widely. As this project need same Internet source to connect ESP8266 NodeMCU and ThingSpeak, the project was able to connect with Internet but in small range of coverage. It should be upgraded by using Internet wherever the place is.

Comments

Popular posts from this blog

Week 10 (30/9/2019 - 4/10/2019)

On 2 Oct 2019, a FYP 2 Briefing had been covering: FYP 2 Exhibition Day (Tips & Tricks) and Submission of Progress Report, Final Report & Technical Paper. Students were able to know the tips and how to present their projects during Exhibition Day. The speaker also brief on Submission of Progress Report, Final Report & Technical Paper. Next, a sketch has been made for this project. Google Sketch Up used to draw the casing of the project. A sketch need to be provided some Braille cell for guidance to the blind people.   Left View of the Project Right View of the Project

Week 2 (29/7/2019-2/8/2019)

On 31 July 2019, a workshop regarding Introductory Briefing is held at TTL1 at 3:00pm. The contents are about : Code, Credit & CLOs Assessments & Weightage - 20% Logbook/Blog - 35% FYP Exhibition Day - 35% Final Report - 10% Technical Paper Getting FYP 2 Information - Telegram - Unikl BMI FYP website - FYP2 Academic Calendar - FYP Committee Finalize FYP 2 Title FYP Project Claim - RM500 per student Misconception About FYP FYP Progress Report - Project planning - Project design - Description on the project block diagram and flow chart - Circuit description and operation - List of components used - PCB LayoutData collection/results -Conclusion FYP Thesis - Chapter 1: Introduction - Chapter 2: Literature review - Chapter 3: Methodology - Chapter 4: Results and Discussion - Chapter 5: Conclusion & Recommendations FYP 2 Activities              On 1 August 2019, I print out the Change of Title Form from the UniKL BMI Final Year Proj...

Week 15 (4/11/2019 - 8/11/2019)

Task: Updating Chapter 4. This chapter includes the findings explanation and the data analysis. During develop this project, most important things that need to be carried out were the objectives. Result 1: Accuracy of Pulse Sensor Circuit Analysis To determine the accuracy of the pulse detector circuit, an experimental analysis was conducted on the pulse sensor circuit. In patient monitor and pulse sensor, heart rate measuring is compared between the pulse oximeter. Here is the contrast between the pulse oximeter and the pulse sensor for reading the heart rate. Comparison of Heart Beat Accuracy between Pulse Oximeter and Pulse Sensor between Five Students Result 2: Classifier Analysis with Audio Output The purpose of this experiment is to determine whether the heart rate status generated by the earphone using Cytron EasyMP3 Shield is consistent with the current heart status displayed through Serial Monitor on Arduino IDE. This is to ensure that the audio was pr...